FGM

ResourceID
spase://CNES/Instrument/CDPP-AMDA/Cluster1/FGM

Description

FGM (Fluxgate Magnetometer) consists of two tri-axial fluxgate magnetometers mounted on one of the two 5 m radial booms, plus a data processing unit (DPU) on the main equipment platform. The magnetometer boom lies in the spacecraft spin plane, with the outboard sensor at the boom tip and the inboard sensor mounted 1.5 m inboard from the tip, to minimize the importance of the spacecraft background magnetic field and its variations. The sensors are mounted such that the X axes are aligned with the spacecraft spin axis, and the other axes are in the spin plane. There are five sensitivity ranges, from +/- 256 nT to +/- 65,500 nT (used only to facilitate ground testing). Range switching can be automatic or by command. Calibration is done by introducing a known current step into the feedback loop of the sensors. Telemetry allocation limits the normal output to about 20 vectors/s.

View XML | View JSON | Edit

Details

Version:2.4.1

Instrument

ResourceID
spase://CNES/Instrument/CDPP-AMDA/Cluster1/FGM
ResourceHeader
ResourceName
FGM
AlternateName
Fluxgate Magnetometer
ReleaseDate
2016-11-04 15:37:46Z
Description

FGM (Fluxgate Magnetometer) consists of two tri-axial fluxgate magnetometers mounted on one of the two 5 m radial booms, plus a data processing unit (DPU) on the main equipment platform. The magnetometer boom lies in the spacecraft spin plane, with the outboard sensor at the boom tip and the inboard sensor mounted 1.5 m inboard from the tip, to minimize the importance of the spacecraft background magnetic field and its variations. The sensors are mounted such that the X axes are aligned with the spacecraft spin axis, and the other axes are in the spin plane. There are five sensitivity ranges, from +/- 256 nT to +/- 65,500 nT (used only to facilitate ground testing). Range switching can be automatic or by command. Calibration is done by introducing a known current step into the feedback loop of the sensors. Telemetry allocation limits the normal output to about 20 vectors/s.

Contacts
RolePersonStartDateStopDateNote
1.PrincipalInvestigatorspase://SMWG/Person/Chris.Carr
InformationURL
Name
ESA web page
URL
Description

Fluxgate Magnetometer

InformationURL
Name
NSSDC's Master Catalog
URL
Description

Information about the Fluxgate Magnetometer (FGM) experiment on the Cluster 2/FM5 (Rumba) mission.

InstrumentType
Magnetometer
InvestigationName
Fluxgate Magnetometer (FGM) on Cluster 2/FM5 (Rumba)
OperatingSpan
StartDate
2000-12-01 00:00:00
Note
Start of full orbit coverage: 2002-06-01T00:00:00
ObservatoryID