ESP

ResourceID
spase://CNES/Instrument/CDPP-AMDA/FREJA/ESP

Description

The electron data are a collection of detections made by the MATE and TESP instruments on Freja.

  The MAgnetic imaging Two-dimensional Electron spectrometer (MATE) measures electron energy and angular distributions in the energy range 
  0.1 - 100 keV. MATE consist of a 360° field-of-view sector magnet energy analyser with 90° deflection angle for simultaneous energy and 
  pitch angle determination. The sampling rate for the full energy range is 10 ms, and acollimator system enables measurements of the 
  energy spectrum at 16 energies , and 30 angular sectors. Unfortunately, the MATE instrument was not deployed completely and was to 1/3 
  blocked by the Freja spacecraft itself and only every 4th angular sector have data. Also, the MATE instrument did only work properly up 
  to orbits around 1600, where after only the integrated flux of the high-energy electrons could be obtained. In addition, the lowest energy 
  channels was found to give uncertain data.
  
  The Two-dimensional Electron SPectrometer (TESP) on Freja consists of a "top-hat" style sweeping electrostatic analyser. The energy range 
  of 20-25 keV is covered in 32 sectors to complete a spectrum. Depending on instrument mode, 16 or 32 spectra are returned each second 
  (31.25 ms resolution). The angular field-of-view is the full 360° and electrons are counted in 32 equally spaced bins, yielding an angular 
  resolution of 11°. The entrance aperture of the TESP also contains a set of electrostatic deflectors which allows the plane of acceptance 
  to be "warped" into a cone. 
  The TESP experiment started working around orbit 720, when the instrument software were sent tot the spacecraft after the launch. The TESP 
  data covers only energies up to 25 keV, but gives nervertheless important information regarding the high-energy electrons. Since low energy 
  electrons may cause an excess emission of secondary electrons (and thereby mitigate charging), the information from this experiment is very 
  useful. Note that the energy channels below about 30 eV was found to give uncertain data.

View XML | View JSON | Edit

Details

Version:2.4.1

Instrument

ResourceID
spase://CNES/Instrument/CDPP-AMDA/FREJA/ESP
ResourceHeader
ResourceName
ESP
AlternateName
Electron Spectrometers
ReleaseDate
2004-07-20 21:10:13Z
Description

The electron data are a collection of detections made by the MATE and TESP instruments on Freja.

  The MAgnetic imaging Two-dimensional Electron spectrometer (MATE) measures electron energy and angular distributions in the energy range 
  0.1 - 100 keV. MATE consist of a 360° field-of-view sector magnet energy analyser with 90° deflection angle for simultaneous energy and 
  pitch angle determination. The sampling rate for the full energy range is 10 ms, and acollimator system enables measurements of the 
  energy spectrum at 16 energies , and 30 angular sectors. Unfortunately, the MATE instrument was not deployed completely and was to 1/3 
  blocked by the Freja spacecraft itself and only every 4th angular sector have data. Also, the MATE instrument did only work properly up 
  to orbits around 1600, where after only the integrated flux of the high-energy electrons could be obtained. In addition, the lowest energy 
  channels was found to give uncertain data.
  
  The Two-dimensional Electron SPectrometer (TESP) on Freja consists of a "top-hat" style sweeping electrostatic analyser. The energy range 
  of 20-25 keV is covered in 32 sectors to complete a spectrum. Depending on instrument mode, 16 or 32 spectra are returned each second 
  (31.25 ms resolution). The angular field-of-view is the full 360° and electrons are counted in 32 equally spaced bins, yielding an angular 
  resolution of 11°. The entrance aperture of the TESP also contains a set of electrostatic deflectors which allows the plane of acceptance 
  to be "warped" into a cone. 
  The TESP experiment started working around orbit 720, when the instrument software were sent tot the spacecraft after the launch. The TESP 
  data covers only energies up to 25 keV, but gives nervertheless important information regarding the high-energy electrons. Since low energy 
  electrons may cause an excess emission of secondary electrons (and thereby mitigate charging), the information from this experiment is very 
  useful. Note that the energy channels below about 30 eV was found to give uncertain data.
Contacts
RolePersonStartDateStopDateNote
1.PrincipalInvestigatorspase://SMWG/Person/Manfred.H.Boehm
2.ProjectScientistspase://SMWG/Person/Jan-Erik.Wahlund
InformationURL
InstrumentType
Spectrometer
InvestigationName
Electron Spectrometers
OperatingSpan
StartDate
1992-11-03 00:00:00
StopDate
1994-10-04 23:59:59
ObservatoryID