HPDE.io

MAG (ASM/VFM)

ResourceID
spase://CNES/Instrument/CDPP-AMDA/SWARM-C/MAG

Description
  • The Absolute Scalar Magnetometer (ASM) measures the magnetic field intensity at the tip of the boom. The ASM is an absolute instrument, i.e. it is not subject to changes of its intrinsic parameters over time. It uses the PPS as the absolute, external reference.
    * The Vector Field Magnetometer (VFM) measures the magnetic field vector at the tip of the optical bench on the boom. The sensor is a 3-axis Compact Spherical Coil (CSC) with a 3-axis Compact Detector Coil (CDC) inside. The instrument operates as a closed-loop system adjusting the compensating CSC currents to maintain a null field at the detector coils within the sphere. The VFM is an analogue instrument and as such subject to temporal changes due to radiation and aging effects of the electronics. The effects are only significant in the bias and linear scale parameters of the characterization; hence these parameters are estimated daily through a comparison of the VFM output with the ASM scalar magnetometer output.

View XML | View JSON | Edit

Details

Version:2.4.1

Instrument

ResourceID
spase://CNES/Instrument/CDPP-AMDA/SWARM-C/MAG
ResourceHeader
ResourceName
MAG (ASM/VFM)
AlternateName
Absolute Scalar Magnetometer / Vector Field Magnetometer
ReleaseDate
2016-11-04 15:37:46Z
Description
  • The Absolute Scalar Magnetometer (ASM) measures the magnetic field intensity at the tip of the boom. The ASM is an absolute instrument, i.e. it is not subject to changes of its intrinsic parameters over time. It uses the PPS as the absolute, external reference.
    * The Vector Field Magnetometer (VFM) measures the magnetic field vector at the tip of the optical bench on the boom. The sensor is a 3-axis Compact Spherical Coil (CSC) with a 3-axis Compact Detector Coil (CDC) inside. The instrument operates as a closed-loop system adjusting the compensating CSC currents to maintain a null field at the detector coils within the sphere. The VFM is an analogue instrument and as such subject to temporal changes due to radiation and aging effects of the electronics. The effects are only significant in the bias and linear scale parameters of the characterization; hence these parameters are estimated daily through a comparison of the VFM output with the ASM scalar magnetometer output.
Contacts
RolePersonStartDateStopDateNote
1.PrincipalInvestigatorspase://CNES/Person/CDPP-AMDA/G.Hulot
InformationURL
InformationURL
InstrumentType
Magnetometer
InvestigationName
Absolute Scalar Magnetometer / Vector Field Magnetometer
OperatingSpan
StartDate
2013-12-02 00:00:00
ObservatoryID