Data follow a 4-second cadence when MAVEN is at an altitude of less than 500 km, otherwise the time cadence is 8 seconds.
The in situ key parameters contain 235 parameters selected by the instrument leads and other MAVEN scientists. These data consist of values derived from L2 data provided by the in situ instruments.
STATIC key parameters include :
* H+, O+, O2+ below : density - number density below TBD altitude determined from APID c6 (32 energy x 64 mass) while in Ram or Conic modes
* H+, O+, O2+ below : temperature - RAM temperature below TBD altitude determined from APID c6 (32 energy x 64 mass) while in Ram or Conic modes
* O2+ below : v_mso - O2+ flow velocity in MSO below TBD altitude determined from APID c8 while in Ram or Conic mode
* H+, He++, O+, O2+ above : flux - omni-directional flux above TBD altitude determined from APID c6 while in Pickup, Eclipse and Protect mode
* H+, He++, O+, O2+ above : flux energy - omni-directional characteristic energy above TBD altitude determined from APID c6 while in Pickup, Eclipse and Protect mode
* H+ above : direction mso - H+ MSO direction of flux above TBD altitude determined from TBD APID while in Pickup and Scan mode
* H+ above : die angular width - H+ flux angular width above TBD altitude determined from TBD APID while in Pickup and Scan mode
* pickup above : direction mso - Dominant pickup ion MSO direction of flux above TBD altitude determined from APID D0 and CE while in Pickup, Eclipse and Protect mode
* pickup above : dir angular width - Dominant pickup ion flux angular width above TBD altitude determined from APID D0 and CE while in Pickup, Eclipse and Protect mode
Version:2.4.1
Data follow a 4-second cadence when MAVEN is at an altitude of less than 500 km, otherwise the time cadence is 8 seconds.
The in situ key parameters contain 235 parameters selected by the instrument leads and other MAVEN scientists. These data consist of values derived from L2 data provided by the in situ instruments.
STATIC key parameters include :
* H+, O+, O2+ below : density - number density below TBD altitude determined from APID c6 (32 energy x 64 mass) while in Ram or Conic modes
* H+, O+, O2+ below : temperature - RAM temperature below TBD altitude determined from APID c6 (32 energy x 64 mass) while in Ram or Conic modes
* O2+ below : v_mso - O2+ flow velocity in MSO below TBD altitude determined from APID c8 while in Ram or Conic mode
* H+, He++, O+, O2+ above : flux - omni-directional flux above TBD altitude determined from APID c6 while in Pickup, Eclipse and Protect mode
* H+, He++, O+, O2+ above : flux energy - omni-directional characteristic energy above TBD altitude determined from APID c6 while in Pickup, Eclipse and Protect mode
* H+ above : direction mso - H+ MSO direction of flux above TBD altitude determined from TBD APID while in Pickup and Scan mode
* H+ above : die angular width - H+ flux angular width above TBD altitude determined from TBD APID while in Pickup and Scan mode
* pickup above : direction mso - Dominant pickup ion MSO direction of flux above TBD altitude determined from APID D0 and CE while in Pickup, Eclipse and Protect mode
* pickup above : dir angular width - Dominant pickup ion flux angular width above TBD altitude determined from APID D0 and CE while in Pickup, Eclipse and Protect mode
Role | Person | StartDate | StopDate | Note | |
---|---|---|---|---|---|
1. | PrincipalInvestigator | spase://SMWG/Person/James.P.McFadden | |||
2. | DataProducer | spase://CNES/Person/CDPP-AMDA/P.Dunn |
Web Service to this product using the HAPI interface.
Access to Data via CDPP/AMDA Web application.
H+ number density below TBD altitude determined from APID c6 (32 energy x 64 mass) while in Ram or Conic modes
H+ temperature below TBD altitude determined from APID c6 (32 energy x 64 mass) while in Ram or Conic modes
Number of counts in the measurement
O+ number density below TBD altitude determined from APID c6 (32 energy x 64 mass) while in Ram or Conic modes
O+ temperatue below TBD altitude determined from APID c6 (32 energy x 64 mass) while in Ram or Conic modes
Number of counts in the measurement
O2+ number density below TBD altitude determined from APID c6 (32 energy x 64 mass) while in Ram or Conic modes
O2+ temperatue below TBD altitude determined from APID c6 (32 energy x 64 mass) while in Ram or Conic modes
Number of counts in the measurement
O2+ MSO velocity below TBD altitude while in Ram or Conic mode
Number of counts in the measurement
H+ omni-directional flux above TBD altitude determined from APID c6 while in Pickup, Eclipse and Protect mode
H+ omni-directional characteristic energy above TBD altitude determined from APID c6 while in Pickup, Eclipse and Protect mode
Number of counts in the measurement
He++ omni-directional flux above TBD altitude determined from APID c6 while in Pickup, Eclipse and Protect mode
He++ omni-directional characteristic energy above TBD altitude determined from APID c6 while in Pickup, Eclipse and Protect mode
Number of counts in the measurement
O+ omni-directional flux above TBD altitude determined from APID c6 while in Pickup, Eclipse and Protect mode
O+ omni-directional characteristic energy above TBD altitude determined from APID c6 while in Pickup, Eclipse and Protect mode
Number of counts in the measurement
O2+ omni-directional flux above TBD altitude determined from APID c6 while in Pickup, Eclipse and Protect mode
O2+ omni-directional characteristic energy above TBD altitude determined from APID c6 while in Pickup, Eclipse and Protect mode
Number of counts in the measurement
H+ MSO direction of flux above TBD altitude determined from TBD APID while in Pickup and Scan mode
H+ flux angular width above TBD altitude determined from TBD APID while in Pickup and Scan mode
Number of counts in the measurement
Dominant pickup ion MSO direction of flux above TBD altitude determined from APID D0 and CE while in Pickup, Eclipse and Protect mode
Dominant pickup ion flux angular width above TBD altitude determined from APID D0 and CE while in Pickup, Eclipse and Protect mode
Number of counts in the measurement