Solar Orbiter, Level 2 Data, Energetic Particle Detector, SupraThermal Electrons and Protons, Rates.
STEP is designed to measure electrons and ions in the suprathermal energy range (280 keV). To
allow for the separation of electrons and ions, STEP has 2 different channels, each equipped with its
own solid state detectors for detecting particles:
* Magnet channel. Uses a permanent magnet to deflect electrons, measuring only ions (mostly protons).
* Integral channel. Measures all incoming particles.
The electron flux is recovered by subtracting the magnet channel measurements from the integral
channel ones. Each channel is divided in 15 sectors, disposed in 3 rows of 5 pixels, providing
directional information of the incoming particles within the field of view. An additional pixel, not directly
exposed to the incoming flux, measures the cosmic ray background.
Version:2.4.1
Solar Orbiter, Level 2 Data, Energetic Particle Detector, SupraThermal Electrons and Protons, Rates.
STEP is designed to measure electrons and ions in the suprathermal energy range (280 keV). To
allow for the separation of electrons and ions, STEP has 2 different channels, each equipped with its
own solid state detectors for detecting particles:
* Magnet channel. Uses a permanent magnet to deflect electrons, measuring only ions (mostly protons).
* Integral channel. Measures all incoming particles.
The electron flux is recovered by subtracting the magnet channel measurements from the integral
channel ones. Each channel is divided in 15 sectors, disposed in 3 rows of 5 pixels, providing
directional information of the incoming particles within the field of view. An additional pixel, not directly
exposed to the incoming flux, measures the cosmic ray background.
Role | Person | StartDate | StopDate | Note | |
---|---|---|---|---|---|
1. | PrincipalInvestigator | spase://CNES/Person/CDPP-AMDA/J.Rodrigues-Pacheco |
Web Service to this product using the HAPI interface.
Access to Data via CDPP/AMDA Web application.
Magnet channel. Uses a permanet magnet to deflect electrons. Measuring only ions (mostly protons)
Uncertainty in sector averaged magnet channel flux
Sector averaged magnet channel count rate
The electron flux is recovered by subtracting the magnet channel measurements from the integral channel ones
Integral channel. Measures all incoming particles
Uncertainty in sector averaged integral channel flux
Sector averaged integral channel count rate
0: Bad, 1: Known problems, 2: Survey data, 3: Good, 4: Excellent