HPDE.io

Double Star 2 LFEW Summary Parameters

ResourceID
spase://CNES/NumericalData/CDPP-Archive/DoubleStar2/LFEW/DSTAR_SP_T2_LFE

Description

The Low Frequency Electromagnetic Wave Detector (LFEW) is a search-coil type three-component electromagnetic wave detector, with a frequency range from 8 Hz to 10 kHz in three frequency segments (8-100 Hz, 100-1000 Hz, and 1-10 kHz). It is designed to measure low frequency magnetic waves in different regions of the magnetosphere.

This data set contains Double Star 2 LFEW summary parameters at 1 min reslution including the instrument status and the components of the wave spectral density parallel and perpendicular to the magnetic field in three frequency bands each.

View XML | View JSON | Edit

Details

Version:2.4.0

NumericalData

ResourceID
spase://CNES/NumericalData/CDPP-Archive/DoubleStar2/LFEW/DSTAR_SP_T2_LFE
ResourceHeader
ResourceName
Double Star 2 LFEW Summary Parameters
DOI
https://doi.org/10.24400/802406/btez-6ryg
ReleaseDate
2021-11-02 15:44:52Z
Description

The Low Frequency Electromagnetic Wave Detector (LFEW) is a search-coil type three-component electromagnetic wave detector, with a frequency range from 8 Hz to 10 kHz in three frequency segments (8-100 Hz, 100-1000 Hz, and 1-10 kHz). It is designed to measure low frequency magnetic waves in different regions of the magnetosphere.

This data set contains Double Star 2 LFEW summary parameters at 1 min reslution including the instrument status and the components of the wave spectral density parallel and perpendicular to the magnetic field in three frequency bands each.

Contacts
RolePersonStartDateStopDateNote
1.PrincipalInvestigatorspase://CNES/Person/CDPP-Archive/Jinbin.Cao
AccessInformation
RepositoryID
Availability
Online
AccessURL
Name
REGARDS
URL
Description

Access via CNES Data Archive for CDPP

Format
CDF
ProcessingLevel
Calibrated
InstrumentIDs
MeasurementType
MagneticField
MeasurementType
InstrumentStatus
TemporalDescription
TimeSpan
StartDate
2004-05-15 00:00:00Z
StopDate
2006-10-30 00:00:00Z
ObservedRegion
Earth.Magnetosphere
ObservedRegion
Earth.Magnetosphere.Magnetotail
ObservedRegion
Earth.Magnetosphere.Main
ObservedRegion
Earth.Magnetosphere.RadiationBelt
ObservedRegion
Earth.NearSurface.Ionosphere
ObservedRegion
Earth.NearSurface.Plasmasphere
Parameter #1
Name
Double Star 2 LFEW Magnetic field Power spectral density parallel to B0 (8 - 100 Hz) Summary Parameter
Description

Double Star 2 LFEW Magnetic field Power spectral density parallel to B0 (8 - 100 Hz) Summary Parameter

Units
nT^2 Hz^-1
Field
Qualifier
Scalar
FieldQuantity
Magnetic
FrequencyRange
Low
8
High
100
Units
Hz
Parameter #2
Name
Double Star 2 LFEW Magnetic field Power spectral density parallel to B0 (100 - 1000 Hz) Summary Parameter
Description

Double Star 2 LFEW Magnetic field Power spectral density parallel to B0 (100 - 1000 Hz) Summary Parameter

Units
nT^2 Hz^-1
Field
Qualifier
Scalar
FieldQuantity
Magnetic
FrequencyRange
Low
100
High
1000
Units
Hz
Parameter #3
Name
Double Star 2 LFEW Magnetic field Power spectral density parallel to B0 (1000 - 10000 Hz) Summary Parameter
Description

Double Star 2 LFEW Magnetic field Power spectral density parallel to B0 (1000 - 10000 Hz) Summary Parameter

Units
nT^2 Hz^-1
Field
Qualifier
Scalar
FieldQuantity
Magnetic
FrequencyRange
Low
1000
High
10000
Units
Hz
Parameter #4
Name
Double Star 2 LFEW Magnetic field Power spectral density Perpendicular to B0 (8 - 100 Hz) Summary Parameter
Description

Double Star 2 LFEW Magnetic field Power spectral density Perpendicular to B0 (8 - 100 Hz) Summary Parameter

Units
nT^2 Hz^-1
Field
Qualifier
Scalar
FieldQuantity
Magnetic
FrequencyRange
Low
8
High
100
Units
Hz
Parameter #5
Name
Double Star 2 LFEW Magnetic field Power spectral density Perpendicular to B0 (100 - 1000 Hz) Summary Parameter
Description

Double Star 2 LFEW Magnetic field Power spectral density Perpendicular to B0 (100 - 1000 Hz) Summary Parameter

Units
nT^2 Hz^-1
Field
Qualifier
Scalar
FieldQuantity
Magnetic
FrequencyRange
Low
100
High
1000
Units
Hz
Parameter #6
Name
Double Star 2 LFEW Magnetic field Power spectral density Perpendicular to B0 (1000 - 10000 Hz) Summary Parameter
Description

Double Star 2 LFEW Magnetic field Power spectral density Perpendicular to B0 (1000 - 10000 Hz) Summary Parameter

Units
nT^2 Hz^-1
Field
Qualifier
Scalar
FieldQuantity
Magnetic
FrequencyRange
Low
1000
High
10000
Units
Hz
Parameter #7
Name
Double Star 2 LFEW Instrument Status
Description

Double Star 2 LFEW Instrument Status

Support
SupportQuantity
Other