Data Access
This data set contains calibrated Housekeeping data provided by the processor unit located nearby the IMA sensor.
Version:2.4.0
This data set contains calibrated Housekeeping data provided by the processor unit located nearby the IMA sensor.
Role | Person | StartDate | StopDate | Note | |
---|---|---|---|---|---|
1. | PrincipalInvestigator | spase://CNES/Person/CDPP-Archive/Stas.Barabash |
Access via CNES Data Archive for CDPP
Last command status. The field takes one of the following values: 0 ok 1 parameter out of range 2 invalid 3 erroneous opcode
Current data reduction mode. The field takes one of the following mode index values: 0 idle 2 Mspo 4 Msis 5 Mexm 8 Nrm0 9 Nrm1 10 Nrm2 11 Nrm3 12 Nrm4 13 Nrm5 14 Nrm6 15 Nrm7 16 Har0 17 Har1 18 Har2 19 Har3 20 Har4 21 Har5 22 Har6 23 Har7 24 Exm0 25 Exm1 26 Exm2 27 Exm3 28 Exm4 29 Exm5 30 Exm6 31 Exm7 32 Test 33 Cal1 34 Cal2 35 Fake
Last command status. This field value has to be decoded in Binary format: bit 0 = Mcp 28V On/Off bit 1 = Opto 28V On/Off bit 2 = Main 28V On/Off bit 3 = Pacc.ref On/Off bit 4 = Grid.ref On/Off bit 5 = Entr.HV.ref On/Off bit 6 = EnyDfl.HV.ref On/Off bit 7 = EnyDfl.LV.ref On/Off 0 = Off 1 = On
MCP 28V switch. The field takes one of the following values: 0 No 1 Yes
Opto 28V switch. The field takes one of the following values: 0 No 1 Yes
Main 28V switch. The field takes one of the following values: 0 No 1 Yes
Post-acceleration mode. The field takes one of the following values: 0 Fixed 1 Alternating
IMA internal SID type.
The new command received toggle 0/1 bit foreach new command returned in Line -First wordcommand return-
The number of 6 byte packets held in the TM-fifoin F8 representation
The Opto HV monitor in kilo-volts
The Mcp HV monitor in kilo-volts
The energy deflection HV monitor in kilo-volts
The energy deflection LV monitor in volts
The post-acceleration HV monitor in kilo-volts
N.A. grid grounded.
The sensor unit temperature in degree Celsius
The DPU temperature in degree Celsius
The energy deflection HV reference value associated with the monitor reading
The post-acceleration low level reference
The direct command switch.
The energy deflection LV reference value associated with the monitor reading
The post-acceleration high level reference
The TM fifo overflow. The field takes one of the following values: 0 No overflow 1 Overflow
The entrance HV reference value associated with the monitor reading
The grid LV reference value associated with the monitor reading
The post-acceleration level. The field takes one of the following values: 0 Low 1 High
The entrance upper HV monitor in kilo-volts
The MCP default reference. That is the target value for ramping
The Opto default reference. That is the target value for ramping
The entrance lower HV monitor in kilo-volts
The MCP current reference value associated with the monitor reading
The Opto current reference value associated with the monitor reading