The Fluxgate Magnetometer (FGM) data products from the Cluster II Rumba spacecraft consist of magnetic field measurements of the Earth's magnetosphere from a few tens of nT in the outer magnetosphere to over 1,000nT at closest approach. Products are provided at three different time resolutions: full resolution, 5 vectors/second resolution and spin resolution. Each calibration file is valid for the period of one orbit defined from perigee to perigee. The full-resolution magnetic field data has no time averaging applied. If the instrument is in normal mode, the data is at approximately 22 Hz resolution. If it is in burst mode, the data is at approximately 67 Hz resolution. The second product is averaged to a time resolution of 5 vectors per second. The third product is averaged over one spacecraft spin where the spin phase for averaging is the same as that used for the Prime Parameter data. Each of the three primary data products contain the following: time, magnetic field vector, magnetic field magnitude, spacecraft position, instrument range, and telementary mode. The magnetic field components and the spacecraft position are in the GSE coordinate system. In addition to the three primary products, there are five support data products: caveats, calibration field accuracy, calibration files, data missing from processed data set, and data removed by validation process. Caveat files are produced when the calibration is known to be changing on short timescales near eclipses and for other events when visible effects have been observed in the data. Calibration accuracy files contain detailed information on the accuracy of the magnetic field data products and can be used to select periods of data. Calibration files contain the nine elements of the 3x3 calibration matrix and the three offsets for each instrument range. Each file is valid for the period of one orbit for which magnetic field data products have been submitted to the Cluster Active Archive. Data gaps are listed for times at the processing stage when no data were taken, or at the data validation stage where invalid data have been removed. For more details, see "The Cluster Active Archive: Studying the Earth's Space Plasma Environment", edited by Dr. Harri Laakso, Matthew G. T. T. Taylor, C. Philippe Escoubet, from which this information was obtained.
Version:2.3.0
The Fluxgate Magnetometer (FGM) data products from the Cluster II Rumba spacecraft consist of magnetic field measurements of the Earth's magnetosphere from a few tens of nT in the outer magnetosphere to over 1,000nT at closest approach. Products are provided at three different time resolutions: full resolution, 5 vectors/second resolution and spin resolution. Each calibration file is valid for the period of one orbit defined from perigee to perigee. The full-resolution magnetic field data has no time averaging applied. If the instrument is in normal mode, the data is at approximately 22 Hz resolution. If it is in burst mode, the data is at approximately 67 Hz resolution. The second product is averaged to a time resolution of 5 vectors per second. The third product is averaged over one spacecraft spin where the spin phase for averaging is the same as that used for the Prime Parameter data. Each of the three primary data products contain the following: time, magnetic field vector, magnetic field magnitude, spacecraft position, instrument range, and telementary mode. The magnetic field components and the spacecraft position are in the GSE coordinate system. In addition to the three primary products, there are five support data products: caveats, calibration field accuracy, calibration files, data missing from processed data set, and data removed by validation process. Caveat files are produced when the calibration is known to be changing on short timescales near eclipses and for other events when visible effects have been observed in the data. Calibration accuracy files contain detailed information on the accuracy of the magnetic field data products and can be used to select periods of data. Calibration files contain the nine elements of the 3x3 calibration matrix and the three offsets for each instrument range. Each file is valid for the period of one orbit for which magnetic field data products have been submitted to the Cluster Active Archive. Data gaps are listed for times at the processing stage when no data were taken, or at the data validation stage where invalid data have been removed. For more details, see "The Cluster Active Archive: Studying the Earth's Space Plasma Environment", edited by Dr. Harri Laakso, Matthew G. T. T. Taylor, C. Philippe Escoubet, from which this information was obtained.
Role | Person | StartDate | StopDate | Note | |
---|---|---|---|---|---|
1. | PrincipalInvestigator | spase://SMWG/Person/Andre.Balogh | |||
2. | ProjectScientist | spase://SMWG/Person/Melvyn.L.Goldstein |
This site provides information concerning the Cluster II Rumba Fluxgate Magnetometer Instrument.
CAA Instrument User Guides, Calibration Reports and ICDS.
Cluster II Rumba Fluxgate Magnetometer (FGM) data; open access but registration is required