HPDE.io

GIRO Ionogram-Derived Ionospheric Characteristics

ResourceID
spase://GBO/NumericalData/GIRO/CHARS/PT15M

Description

Standard ionogram-derived characteristics obtained by Global Ionospheric Radio Observatory (GIRO) operated by University of Massachusetts Lowell. The list of standard URSI characteristics that can be derived from ionograms can be found in the SAO.XML Data Model Specification for standard ionosonde data exchange, Appendix C, https://ulcar.uml.edu/SAOXML/. In order to request the characteristics values from GIRO, it is necessary to call DIDBGetValues() servlet at GIRO server using standard HTTP call that returns a text document. The values in the document are calculated using automatic or manual interpretation of ionogram images. Each measurement is accompanied by a confidence score value (from 0 to 100, 100 is best autoscaled confidence or data obtained manually) and a set of two QD letters (qualitative and descriptive letters per URSI ionogram interpretation manual). When QD letters are set to //, reported value is obtained automatically, all other combinations of the letters correspond to manual scaling.

View XML | View JSON | Edit

Details

Version:2.5.0

NumericalData

ResourceID
spase://GBO/NumericalData/GIRO/CHARS/PT15M
ResourceHeader
ResourceName
GIRO Ionogram-Derived Ionospheric Characteristics
ReleaseDate
2018-06-28 22:02:01Z
RevisionHistory
RevisionEvent
ReleaseDate
2023-07-28 12:30:53
Note
Edited Acknowledgement, AccessURL, InformationURL, and URL in Description, added Contact and updated SPASE version. LNG
Description

Standard ionogram-derived characteristics obtained by Global Ionospheric Radio Observatory (GIRO) operated by University of Massachusetts Lowell. The list of standard URSI characteristics that can be derived from ionograms can be found in the SAO.XML Data Model Specification for standard ionosonde data exchange, Appendix C, https://ulcar.uml.edu/SAOXML/. In order to request the characteristics values from GIRO, it is necessary to call DIDBGetValues() servlet at GIRO server using standard HTTP call that returns a text document. The values in the document are calculated using automatic or manual interpretation of ionogram images. Each measurement is accompanied by a confidence score value (from 0 to 100, 100 is best autoscaled confidence or data obtained manually) and a set of two QD letters (qualitative and descriptive letters per URSI ionogram interpretation manual). When QD letters are set to //, reported value is obtained automatically, all other combinations of the letters correspond to manual scaling.

Acknowledgement
Heavy investments of time, effort, expertise, and funds continue to be made to produce, collect, quality control, interpret, and archive ionosonde data. It is therefore important that the data suppliers and Lowell GIRO Data Center (LGDC) are appropriately acknowledged in scientific publications that include analysis of data obtained from LGDC servers. Please read Rules of the Road https://giro.uml.edu/didbase/RulesOfTheRoad.html for license information and refer to Acknowledgements List https://giro.uml.edu/didbase/acknowledgements.htm to use GIRO data per license requirements.
Contacts
RolePersonStartDateStopDateNote
1.PrincipalInvestigatorspase://SMWG/Person/Bodo.W.Reinisch
2.DataProducer
TechnicalContact
spase://SMWG/Person/Ivan.A.Galkin
3.MetadataContactspase://SMWG/Person/Leonard.N.Garcia
InformationURL
Name
GIRO (Global Ionospheric Radio Observatory) Home Page
URL
Description

Access to real-time data and software tools

Language
en
Association
AssociationID
AssociationType
DerivedFrom
PriorIDs
spase://VWO/NumericalData/GIRO/CHARS.PT15M
spase://VSPO/NumericalData/GIRO/CHARS/PT15M
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
GIRO access to ionogram-derived ionospheric characteristics
URL
Description

GIRO webpage that accesses DIDBase repository and retrieves the list of characteristics.

Language
en
Format
Text.ASCII
Encoding
ASCII
Acknowledgement
Heavy investments of time, effort, expertise, and funds continue to be made to produce, collect, quality control, interpret, and archive ionosonde data. It is therefore important that the data suppliers and Lowell GIRO Data Center (LGDC) are appropriately acknowledged in scientific publications that include analysis of data obtained from LGDC servers. Please read Rules of the Road https://giro.uml.edu/didbase/RulesOfTheRoad.html for license information and refer to Acknowledgements List https://giro.uml.edu/didbase/acknowledgements.htm to use GIRO data per license requirements.
ProcessingLevel
Calibrated
ProviderProcessingLevel
Ionogram-scaled ionospheric characteristics in physical units.
InstrumentIDs
MeasurementType
Waves.Active
TemporalDescription
TimeSpan
StartDate
1987-01-01 00:00:05Z
RelativeStopDate
P 5M
Note
Cadence of ionogram measurements may vary depending on the scheduling requirements at GIRO sites; 15 minutes is nominal cadence
Cadence
PT15M
Exposure
PT1M
SpectralRange
RadioFrequency
ObservedRegion
Earth.NearSurface.Ionosphere
Caveats
Data coverage is varying among different GIRO instrument locations
Keywords
Ionogram
Ionospheric Characteristics