HPDE.io

Polar Electric Fields Instrument (EFI), Electric field in GSM coordinates, Realtime Resolution (E_0 version)

ResourceID
spase://NASA/NumericalData/POLAR/EFI/EField/E0/GSM/Realtime/PT0.025S

Description

Electric field in GSM coordinates (E_0 version, from instrument realtime EField.

View XML | View JSON | Edit

Details

Version:2.3.0

NumericalData

ResourceID
spase://NASA/NumericalData/POLAR/EFI/EField/E0/GSM/Realtime/PT0.025S
ResourceHeader
ResourceName
Polar Electric Fields Instrument (EFI), Electric field in GSM coordinates, Realtime Resolution (E_0 version)
ReleaseDate
2020-07-07 21:15:01Z
Description

Electric field in GSM coordinates (E_0 version, from instrument realtime EField.

Acknowledgement
The user will acknowledge, in any publication which uses POLAR EFI data, the instrument PI.
Contacts
RolePersonStartDateStopDateNote
1.PrincipalInvestigatorspase://SMWG/Person/Forrest.S.Mozer
2.MetadataContactspase://SMWG/Person/Jack.B.Vernetti
PriorIDs
spase://VSPO/NumericalData/POLAR/EFI/EField/E0/GMS/Realtime/PT0.025
spase://VWO/NumericalData/POLAR/EFI/EField_E0_GMS_Realtime
spase://VSPO/NumericalData/POLAR/EFI/EField/E0/GSM/Realtime/PT0.025S
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
URL
Description

This URL is the root location of the POLAR EFI archive. It consists of Yearly subdirectories: 1996, 1997, ..., 2008 each of which consists of Monthly subdirectories: 01, 02, ..., 12 The archive files for a given date are located in the corresponding YY/MM subdirectory.

Language
en
Format
CDF
Encoding
None
Acknowledgement
The user will acknowledge, in any publication which uses POLAR EFI data, the instrument PI.
InstrumentIDs
MeasurementType
ElectricField
TemporalDescription
TimeSpan
StartDate
1996-03-16 00:00:00
StopDate
2008-04-12 24:00:00
Cadence
PT0.025S
Parameter #1
Name
Time
ParameterKey
TIME_TAG
Description

Data point time-tags which are double precision floating point numbers which represent the number of seconds, UTC, from midnight of the day represented by the file.

Cadence
PT0.025S
Units
seconds
ValidMin
0.0
ValidMax
86460.0
Support
SupportQuantity
Temporal
Parameter #2
Name
ElectricFieldVector
ParameterKey
DATA_VALUES
Description

Data point vector values which are a triplet of single precision floating point numbers which represent the X,Y,Z components of the electric field. These vectors are in one-to-one correspondence with the values in the TIME_TAG parameter. This data is sampled, and played back in near realtime.

Cadence
PT0.025S
Units
mV/m
CoordinateSystem
CoordinateRepresentation
Cartesian
CoordinateSystemName
GSM
ValidMin
-2000.0
ValidMax
2000.0
Field
Qualifier
Vector
FieldQuantity
Electric