HPDE.io

Polar Electric Fields Instrument (EFI), Electric field in GSE coordinates, Spin Resolution(E_Dot0 version)

ResourceID
spase://NASA/NumericalData/POLAR/EFI/EField/EDot0/GSE/Spin/PT6S

Description

Electric field in GSE coordinates (E_Dot0 version), one vector per spin, computed by a spin-fit algorithm using the realtime electric field measurements.

View XML | View JSON | Edit

Details

Version:2.2.9

NumericalData

ResourceID
spase://NASA/NumericalData/POLAR/EFI/EField/EDot0/GSE/Spin/PT6S
ResourceHeader
ResourceName
Polar Electric Fields Instrument (EFI), Electric field in GSE coordinates, Spin Resolution(E_Dot0 version)
ReleaseDate
2020-07-07 21:15:01Z
Description

Electric field in GSE coordinates (E_Dot0 version), one vector per spin, computed by a spin-fit algorithm using the realtime electric field measurements.

Acknowledgement
The user will acknowledge, in any publication which uses POLAR EFI data, the instrument PI.
Contacts
RolePersonStartDateStopDateNote
1.PrincipalInvestigatorspase://SMWG/Person/Forrest.S.Mozer
2.MetadataContactspase://SMWG/Person/Jack.B.Vernetti
PriorIDs
spase://VWO/NumericalData/POLAR/EFI/EField_EDot0_GSE_Spin
spase://VSPO/NumericalData/POLAR/EFI/EField/EDot0/GSE/Spin/PT6S
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
URL
Description

This URL is the root location of the POLAR EFI archive. It consists of Yearly subdirectories: 1996, 1997, ..., 2008 each of which consists of Monthly subdirectories: 01, 02, ..., 12 The archive files for a given date are located in the corresponding YY/MM subdirectory.

Language
en
Format
CDF
Encoding
None
Acknowledgement
The user will acknowledge, in any publication which uses POLAR EFI data, the instrument PI.
InstrumentIDs
MeasurementType
ElectricField
TemporalDescription
TimeSpan
StartDate
1996-03-16 00:00:00
StopDate
2008-04-12 24:00:00
Cadence
PT6S
Parameter #1
Name
Time
ParameterKey
TIME_TAG
Description

Data point time-tags which are double precision floating point numbers which represent the number of seconds, UTC, from midnight of the day represented by the file.

Cadence
PT6S
Units
seconds
ValidMin
0.0
ValidMax
86460.0
Support
SupportQuantity
Temporal
Parameter #2
Name
ElectricFieldVector
ParameterKey
DATA_VALUES
Description

Data point vector values which are a triplet of single precision floating point numbers which represent the X,Y,Z components of the electric field. These vectors are in one-to-one correspondence with the values in the TIME_TAG parameter. This data is computed by a ground spin-fit algorithm on the realtime electric field and represents one point every spin.

Cadence
PT6S
Units
mV/m
CoordinateSystem
CoordinateRepresentation
Cartesian
CoordinateSystemName
GSE
ValidMin
-2000.0
ValidMax
2000.0
Field
Qualifier
Vector
FieldQuantity
Electric