This data set holds 24-hour-averaged count rates and
related parameters for each of 8 sensors or multi-sensor coincidence modes,
as obtained from the U.Iowa Geiger Tube Telescope (GTT) experiment flown
on Pioneer 11. Data have been corrected for RTG and temperature effects.
Single-sensor count rates are from the A (directional fluxes of
0.04-21 MeV electrons and 0.61-80 MeV protons, plus omnidirectional fluxes
of .GT.21 MeV electrons and .GT.80 MeV protons), B (directional fluxes
of 0.56-21 MeV electrons and 9-80 MeV protons, plus omnidirectional
fluxes of .GT.21 MeV electrons and .GT.80 MeV protons), C (omnidirectional
fluxes of .GT.21 MeV electrons and .GT.80 MeV protons), D (omnidirectional
fluxes of .GT.31 MeV electrons and .GT.80 MeV protons), and G (directional
fluxes of 0.61-3.41 MeV protons) Geiger tubes. Coincidence mode rates
are given for Geiger tube combinations (A,B), (A,B,C) and (D,E,F).
The G and (A,B,C) rates are each given multiple times in the 12 rates
of each 24-hr record. Additional parameters associated with each count
rate include numbers of counts contributing to each count rate, the
statistical uncertainty in each rate, and others used in U. Iowa's
processing and carried along for posterity. These are described in
the document identified in the first "Information URL." The data were
provided to NSSDC on a VMS-binary-formatted CD-ROM and were converted to
ASCII by GSFC/SPDF in 2010. The data are ftp-accessible in a single
9-MB file and are also accessible with graphical display from an
FTPBrowser interface.
Version:2.2.9
This data set holds 24-hour-averaged count rates and
related parameters for each of 8 sensors or multi-sensor coincidence modes,
as obtained from the U.Iowa Geiger Tube Telescope (GTT) experiment flown
on Pioneer 11. Data have been corrected for RTG and temperature effects.
Single-sensor count rates are from the A (directional fluxes of
0.04-21 MeV electrons and 0.61-80 MeV protons, plus omnidirectional fluxes
of .GT.21 MeV electrons and .GT.80 MeV protons), B (directional fluxes
of 0.56-21 MeV electrons and 9-80 MeV protons, plus omnidirectional
fluxes of .GT.21 MeV electrons and .GT.80 MeV protons), C (omnidirectional
fluxes of .GT.21 MeV electrons and .GT.80 MeV protons), D (omnidirectional
fluxes of .GT.31 MeV electrons and .GT.80 MeV protons), and G (directional
fluxes of 0.61-3.41 MeV protons) Geiger tubes. Coincidence mode rates
are given for Geiger tube combinations (A,B), (A,B,C) and (D,E,F).
The G and (A,B,C) rates are each given multiple times in the 12 rates
of each 24-hr record. Additional parameters associated with each count
rate include numbers of counts contributing to each count rate, the
statistical uncertainty in each rate, and others used in U. Iowa's
processing and carried along for posterity. These are described in
the document identified in the first "Information URL." The data were
provided to NSSDC on a VMS-binary-formatted CD-ROM and were converted to
ASCII by GSFC/SPDF in 2010. The data are ftp-accessible in a single
9-MB file and are also accessible with graphical display from an
FTPBrowser interface.
Role | Person | StartDate | StopDate | Note | |
---|---|---|---|---|---|
1. | GeneralContact | spase://SMWG/Person/Bruce.A.Randall |
U.Iowa-written nssdcftp-resident descriptive document
Readme with format statement for this ASCII version
Graphical display, etc.
In CDF via HTTP from SPDF
Count rate due to directional fluxes of
0.04-21 MeV electrons and 0.61-80 MeV protons, plus omnidirectional
fluxes of .GT.21 MeV electrons and .GT.80 MeV protons
Count rate due to directional fluxes of
0.56-21 MeV electrons and 9-80 MeV protons, plus omnidirectional
fluxes of .GT.21 MeV electrons and .GT.80 MeV protons
Count rate due to omnidirectional fluxes of
.GT.21 MeV electrons and .GT.80 MeV protons
Count rate due to omnidirectional fluxes of
.GT.31 MeV electrons and .GT.80 MeV protons
Count rate due to directional fluxes of
0.61-3.41 Mev protons. See also columns 36 and 43.
(A,B) coincidence mode count rate due to directional fluxes of
.GT.21 MeV electrons and .GT.130 MeV protons.
(A,B,C) coincidence mode count rate due to directional fluxes of
.GT.21 MeV electrons and .GT.130 MeV protons. See also columns 41 and 44.
(D,E,F) coincidence mode count rate due to omnidirectional
fluxes of .GT.31 MeV electrons and .GT.150 MeV protons. E and F are Geiger
tubes whose individual count rates are not taken.
Standard deviations [count rate/SQRT(#points)]
in each of the 12 count rates of columns 33-44.
Standard deviation in the count rates in Columns
33 to 44, respectively
Number of raw counts in each of the 12 count
rates in columns 33-44
numbers of counts in the count rates in Columns
33 to 44, respectively
In sequence, data words are: Earth-spacecraft
distance, AU; Earth-sun distance, AU; Sun-spacecraft distance, AU;
celestial longitude of Earth; celestial longitude of spacecraft;
longitude of solar equator + 270; celestial latitude of Earth;
celestial latitude of spacecraft; heliographic latitude of spacecraft;
heliographic latitude of Earth.
Positional parameters for spacecraft and earth