HPDE.io

Voyager 1 Saturn Plasma Wave Spectrometer (PWS) Resampled Spectral Analyzer, Version 1.0, 48 s Data

ResourceID
spase://NASA/NumericalData/Voyager1/PWS/Saturn/PT48S

Description
  • Data Set Overview
  • =================

+-------------------------------------------------+
| Data Characteristics | Value |


| Instrument P.I. | DONALD A. GURNETT |
| Data Supplier | WILLIAM S. KURTH |
| Data Sampling Rate | 48 SECONDS |
| Data Set Start Time | 1981-08-24T00:00:00.000Z |
| Data Set Stop Time | 1981-08-31T23:59:12.000Z |
+-------------------------------------------------+

  • Data Set Description
  • ====================

This Data Set consists of 48 s calibrated, averaged Wave Electric Field Intensities from the Voyager 1 Plasma Wave Receiver Spectrum Analyzer obtained in the Vicinity of the Jovian Magnetosphere. For each 48 s Interval, a geometric average Field Strength is determined for each of the 16 Spectrum Analyzer Channels whose Center Frequencies range from 10 Hz to 56.2 kHz and which are logarithmically spaced in Frequency, four Channels per Decade. The Time associated with each Set of Averages is the Beginning of the Averaging Interval. Averages are stored in Units of V/m. During Data Gaps where complete 48 s Intervals are missing, no Entries exist in the File, that is, the Gaps are not Zero-filled or Tagged in any other way. Additional Information about this Data Set and the Instrument which produced it can be found elsewhere in this Catalog. An Overview of the Data in this Data Set can be found in (Gurnett et al., 1979) and a complete Instrument Description can be found in (Scarf and Gurnett, 1977).

+-----------------------------------------+
| Processing Characteristics | Value |


| Processing Level ID | 4 |
| Software Flag | Y |
| Processing Start Time | 1988-02-01 |
+-----------------------------------------+

  • Parameters
  • ==========

+-------------------------------------------------------+
| Parameter Characteristics | Value |


| Sampling Parameter Name | TIME |
| Data Set Parameter Name | PLASMA WAVE SPECTRUM |
| Sampling Parameter Resolution | 48.000000 |
| Minimum Sampling Parameter | 197708201553.000000 |
| Sampling Parameter Interval | 48.000000 |
| Minimum Available Sampling Int | 4.000000 |
| Data Set Parameter Unit | VOLT/METER |
| Noise Level | 0.000005 |
| Sampling Parameter Unit | SECOND |
+-------------------------------------------------------+

A Set of derived Parameters consisting of Wave Electric Field Intensities or Electric Field Spectral Densities at various contiguous Frequencies over a Range of Frequencies. The MKS Units are: V/m or V^2/(Hz m^2), respectively.

  • Source Instrument Parameters
  • ============================

+-------------------------------------------------------------------+
| Source Instrument Characteristic | Value |


| Instrument Host ID | VG1 |
| Data Set Parameter Name | PLASMA WAVE SPECTRUM |
| Instrument Parameter Names | ELECTRIC FIELD WAVEFORM |
| | ELECTRIC FIELD COMPONENT |
| | MAGNETIC FIELD COMPONENT |
| | WAVE ELECTRIC FIELD INTENSITY |
| | WAVE MAGNETIC FIELD INTENSITY |
| Important Instrument Parameters | 1 (for all Parameters) |
+-------------------------------------------------------------------+

View XML | View JSON | Edit

Details

Version:2.3.0

NumericalData

ResourceID
spase://NASA/NumericalData/Voyager1/PWS/Saturn/PT48S
ResourceHeader
ResourceName
Voyager 1 Saturn Plasma Wave Spectrometer (PWS) Resampled Spectral Analyzer, Version 1.0, 48 s Data
ReleaseDate
2020-07-07 21:15:55Z
Description
  • Data Set Overview
  • =================

+-------------------------------------------------+
| Data Characteristics | Value |


| Instrument P.I. | DONALD A. GURNETT |
| Data Supplier | WILLIAM S. KURTH |
| Data Sampling Rate | 48 SECONDS |
| Data Set Start Time | 1981-08-24T00:00:00.000Z |
| Data Set Stop Time | 1981-08-31T23:59:12.000Z |
+-------------------------------------------------+

  • Data Set Description
  • ====================

This Data Set consists of 48 s calibrated, averaged Wave Electric Field Intensities from the Voyager 1 Plasma Wave Receiver Spectrum Analyzer obtained in the Vicinity of the Jovian Magnetosphere. For each 48 s Interval, a geometric average Field Strength is determined for each of the 16 Spectrum Analyzer Channels whose Center Frequencies range from 10 Hz to 56.2 kHz and which are logarithmically spaced in Frequency, four Channels per Decade. The Time associated with each Set of Averages is the Beginning of the Averaging Interval. Averages are stored in Units of V/m. During Data Gaps where complete 48 s Intervals are missing, no Entries exist in the File, that is, the Gaps are not Zero-filled or Tagged in any other way. Additional Information about this Data Set and the Instrument which produced it can be found elsewhere in this Catalog. An Overview of the Data in this Data Set can be found in (Gurnett et al., 1979) and a complete Instrument Description can be found in (Scarf and Gurnett, 1977).

+-----------------------------------------+
| Processing Characteristics | Value |


| Processing Level ID | 4 |
| Software Flag | Y |
| Processing Start Time | 1988-02-01 |
+-----------------------------------------+

  • Parameters
  • ==========

+-------------------------------------------------------+
| Parameter Characteristics | Value |


| Sampling Parameter Name | TIME |
| Data Set Parameter Name | PLASMA WAVE SPECTRUM |
| Sampling Parameter Resolution | 48.000000 |
| Minimum Sampling Parameter | 197708201553.000000 |
| Sampling Parameter Interval | 48.000000 |
| Minimum Available Sampling Int | 4.000000 |
| Data Set Parameter Unit | VOLT/METER |
| Noise Level | 0.000005 |
| Sampling Parameter Unit | SECOND |
+-------------------------------------------------------+

A Set of derived Parameters consisting of Wave Electric Field Intensities or Electric Field Spectral Densities at various contiguous Frequencies over a Range of Frequencies. The MKS Units are: V/m or V^2/(Hz m^2), respectively.

  • Source Instrument Parameters
  • ============================

+-------------------------------------------------------------------+
| Source Instrument Characteristic | Value |


| Instrument Host ID | VG1 |
| Data Set Parameter Name | PLASMA WAVE SPECTRUM |
| Instrument Parameter Names | ELECTRIC FIELD WAVEFORM |
| | ELECTRIC FIELD COMPONENT |
| | MAGNETIC FIELD COMPONENT |
| | WAVE ELECTRIC FIELD INTENSITY |
| | WAVE MAGNETIC FIELD INTENSITY |
| Important Instrument Parameters | 1 (for all Parameters) |
+-------------------------------------------------------------------+

Contacts
RolePersonStartDateStopDateNote
1.MetadataContactspase://SMWG/Person/Todd.A.King
2.MetadataContactspase://SMWG/Person/Lee.Frost.Bargatze
InformationURL
Name
VG1-S-PWS-4-SUMM-SA-48SEC-V1.0
URL
Description

The Document describing the Contents of the Collection.

Language
En
PriorIDs
spase://VMO/NumericalData/Voyager1/PWS/Saturn/PT48S
spase://VSPO/NumericalData/Voyager1/PWS/Saturn/PT48S
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
PDS/PPI
URL
ProductKey
VG1-S-PWS-4-SUMM-SA-48SEC-V1.0
Description

This Collection is archived with NASA Planetary Data System.

Language
En
Format
Text.ASCII
Acknowledgement
NASA Planetary Plasma Interactions (PPI) Node of the Planetary Data System (PDS) and the Principal Investigator for the Data.
InstrumentIDs
MeasurementType
Waves.Passive
TemporalDescription
TimeSpan
StartDate
1980-11-11 00:00:00.00
StopDate
1980-11-11 23:59:12.00
Cadence
PT48S
ObservedRegion