HPDE.io

GOES 14 High Energy Proton and Alpha Detector (HEPAD) data at 5 min Time Resolution in Spacecraft Coordinates

ResourceID
spase://NOAA/NumericalData/GOES/14/EPS/HEPAD/S15/PT5M

Description

The GOES 13 High Energy Proton and Alpha Detector (HEPAD) provides flux measurements of high energy proton and alpha particles. For more information, please see Onsager et al. 1996, Operational uses of the GOES energetic particle detectors, in GOES 8 and Beyond, Proc. SPIE, Vol. 2812, edited by E. R. Washwell, pp. 281-290, Bellingham, WA. These data files contain mainly information on the number of particles per average and count rates for the HEPAD sensor. Data files contain long descriptive header.

View XML | View JSON | Edit

Details

Version:2.3.1

NumericalData

ResourceID
spase://NOAA/NumericalData/GOES/14/EPS/HEPAD/S15/PT5M
ResourceHeader
ResourceName
GOES 14 High Energy Proton and Alpha Detector (HEPAD) data at 5 min Time Resolution in Spacecraft Coordinates
AlternateName
GOES 14 HEPAD S15 data
ReleaseDate
2020-05-04 13:45:15Z
Description

The GOES 13 High Energy Proton and Alpha Detector (HEPAD) provides flux measurements of high energy proton and alpha particles. For more information, please see Onsager et al. 1996, Operational uses of the GOES energetic particle detectors, in GOES 8 and Beyond, Proc. SPIE, Vol. 2812, edited by E. R. Washwell, pp. 281-290, Bellingham, WA. These data files contain mainly information on the number of particles per average and count rates for the HEPAD sensor. Data files contain long descriptive header.

Acknowledgement
NASA Office of Space Science Applications (United States), NOAA National Environmental Satellite Service (United States), Terry G. Onsager
Contacts
RolePersonStartDateStopDateNote
1.PrincipalInvestigatorspase://SMWG/Person/Terry.Onsager
2.MetadataContactspase://SMWG/Person/James.M.Weygand
InformationURL
Name
GOES N, O, and P Brochure
URL
Description

Information about the magnetometers onboard GOES 14

Language
en
PriorIDs
spase://VMO/NumericalData/GOES/14/EPEAD/hepad_s15_PT5M
spase://VMO/NumericalData/GOES/14/EPS/hepad_s15_PT5M
spase://VSPO/NumericalData/GOES/14/EPS/HEPAD/S15/PT5M
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
Direct access to the GOES 14 High Energy Proton and Alpha Detector (HEPAD) Data
URL
Description

Direct link to the GOES 14 High Energy Proton and Alpha Detector (HEPAD) data in CSV format as well as the energetic particle data from other GOES spacecraft. The data are sorted by year, month, spacecraft, and file type. The file names indicates the data type, spacecraft number, year, month, and resolution. For example, g14_hepad_s15_5m_20100501_20100531.csv, indicates GOES 14 magnetometer data at 5 min time resolution from 2010-05-01 to 2010-05-31.

Format
Text.ASCII
Encoding
None
Acknowledgement
NASA, NOAA, Terry G. Onsager
ProcessingLevel
Calibrated
ProviderResourceName
NOAA GOES 14 HEPAD
ProviderProcessingLevel
Level-2
InstrumentIDs
MeasurementType
EnergeticParticles
TemporalDescription
TimeSpan
StartDate
2012-10-01 00:00:00
StopDate
2012-11-30 23:59:00
Note
Time format in data files is year-month-day hour:minute:seconds. Data file may fill out the first month and last month with flags.
Cadence
PT5M
Caveats
Flags=-99999.0
Keywords
5 min
geosynchronous
GOES
High Energy Proton and Alpha Detector
Parameter #1
Name
Seconds of the Month
ParameterKey
Time
Description

Time format in data files is year-month-day hour:minute:seconds

Support
SupportQuantity
Temporal
Parameter #2
Name
Quality flag for all particles >110 keV that deposit energy the D1 silicon slab
ParameterKey
S1_QUAL_FLAG
Description

Quality flag non-zero value indicates data quality issue

ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
SupportQuantity
Other
Parameter #3
Name
Number of >110 keV particles per average
ParameterKey
S1_NUM_PTS
Description

Data points per average

ValidMin
0
ValidMax
75
FillValue
0
Particle
ParticleType
Ion
ParticleQuantity
Counts
Parameter #4
Name
Count rate of all particles >110 keV that deposit energy in the D1 silicon slab
ParameterKey
S1_COUNT_RATE
Description

Counts/s from all particles that deposit >110 keV in the D1 silicon slab

Units
s^-1
ValidMin
0.1
ValidMax
1.0e4
FillValue
-99999
Particle
ParticleType
Ion
ParticleQuantity
CountRate
Parameter #5
Name
Quality flag for all particles >110 keV that deposit energy in the D2 silicon slab
ParameterKey
S2_QUAL_FLAG
Description

Quality flag non-zero value indicates data quality issue

ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
SupportQuantity
Other
Parameter #6
Name
Number of >110 keV particles per average
ParameterKey
S2_NUM_PTS
Description

Data points per average

ValidMin
0
ValidMax
75
FillValue
0
Particle
ParticleType
Ion
ParticleQuantity
Counts
Parameter #7
Name
Count rate of all particles that deposit energy in the D2 silicon slab
ParameterKey
S2_COUNT_RATE
Description

Counts/s from all particles that deposit >110 keV in the D2 silicon slab

Units
s^-1
ValidMin
0.1
ValidMax
1.0e4
FillValue
-99999
Particle
ParticleType
Ion
ParticleQuantity
CountRate
Parameter #8
Name
Quality flag for all particles that deposit energy in the photomultiplier tube
ParameterKey
S3_QUAL_FLAG
Description

Quality flag non-zero value indicates data quality issue

ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
SupportQuantity
Other
Parameter #9
Name
Number of particles per average
ParameterKey
S3_NUM_PTS
Description

Data points per average

ValidMin
0
ValidMax
75
FillValue
0
Particle
ParticleType
Ion
ParticleQuantity
Counts
Parameter #10
Name
Count rate of all particles that deposit energy in the photomultiplier tube
ParameterKey
S3_COUNT_RATE
Description

Counts/s from all particles that create >13.5 keV photoelectrons in the photomultiplier tube

Units
s^-1
ValidMin
0.1
ValidMax
1.0e4
FillValue
-99999
Particle
ParticleType
Ion
ParticleQuantity
CountRate
Parameter #11
Name
Quality flag for all particles that deposit energy in the photomultiplier tube
ParameterKey
S4_QUAL_FLAG
Description

Quality flag non-zero value indicates data quality issue

ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
SupportQuantity
Other
Parameter #12
Name
Number of particles per average
ParameterKey
S4_NUM_PTS
Description

Data points per average

ValidMin
0
ValidMax
75
FillValue
0
Particle
ParticleType
Ion
ParticleQuantity
Counts
Parameter #13
Name
Count rate of all particles that deposit energy in the photomultiplier tube
ParameterKey
S4_COUNT_RATE
Description

Counts/s from all particles that create >69 keV photoelectrons in the photomultiplier tube

Units
s^-1
ValidMin
0.1
ValidMax
1.0e4
FillValue
-99999
Particle
ParticleType
Ion
ParticleQuantity
CountRate
Parameter #14
Name
Quality flag for all particles >110 keV that deposit energy in both the D1 and D2 silicon slabs
ParameterKey
S5_QUAL_FLAG
Description

Quality flag non-zero value indicates data quality issue

ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
SupportQuantity
Other
Parameter #15
Name
Number of particles >110 keV per average
ParameterKey
S5_NUM_PTS
Description

Data points per average

ValidMin
0
ValidMax
75
FillValue
0
Particle
ParticleType
Ion
ParticleQuantity
Counts
Parameter #16
Name
Count rate of all particles >110 keV that deposit energy in both the D1 and D2 silicon slabs
ParameterKey
S5_COUNT_RATE
Description

Counts/s from all particles that deposit >110 keV in both the D1 and D2 silicon slabs

Units
s^-1
ValidMin
0.1
ValidMax
1.0e4
FillValue
-99999
Particle
ParticleType
Ion
ParticleQuantity
CountRate