Version:2.3.1
NumericalData
ResourceID
spase://NOAA/NumericalData/GOES/15/EPS/MAGED/19ME2/PT2S
ResourceHeader
ResourceName
GOES 15 Magnetospheric Electron Detector (MAGED) data with energy from 50 to 100 keV at 2 s Time Resolution in Spacecraft Coordinates
AlternateName
GOES 15 MAGED 19ME2 data
ReleaseDate
2020-05-04 13:45:15Z
Description
The GOES 15 Magnetospheric Electron Detector (MAGED) are essentially the same as the Energetic Particle Sensor (EPS) on GOES 8-12. For more information, please see Onsager et al. 1996, Operational uses of the GOES energetic particle detectors, in GOES 8 and Beyond, Proc. SPIE, Vol. 2812, edited by E. R. Washwell, pp. 281-290, Bellingham, WA. These data file contain mainly information on the electron count rates and fluxes from 50 to 100 keV. Data files contain long descriptive header.
Acknowledgement
NASA Office of Space Science Applications (United States), NOAA National Environmental Satellite Service (United States), Terry G. Onsager
Contacts
InformationURL
Name
GOES N, O, and P Brochure
URL
Description
Information about the magnetometers onboard GOES 15
Language
en
PriorIDs
spase://VMO/NumericalData/GOES/14/EPEAD/maged_19me2_PT2S
spase://VMO/NumericalData/GOES/15/EPS/maged_19me2_PT2S
spase://VSPO/NumericalData/GOES/15/EPS/MAGED/19ME2/PT2S
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
Direct access to the GOES 15 Magnetospheric Electron Detector (MAGED) data
URL
Description
Direct link to the GOES 15 Magnetospheric Electron Detector (MAGED) data in CSV format as well as the energetic particle data from other GOES spacecraft. The data are sorted by year, month, spacecraft, and file type. The file names indicates the data type, spacecraft number, year, month, and resolution. For example, g15_maged_19me1_2s_20110617_20110617.csv, indicates GOES 15 magnetometer data at 2 s time resolution for 2011-06-17.
Format
Text.ASCII
Encoding
None
Acknowledgement
NASA, NOAA, Terry G. Onsager
ProcessingLevel
Calibrated
ProviderResourceName
NOAA GOES 15 MAGED
ProviderProcessingLevel
Level-2
InstrumentIDs
MeasurementType
EnergeticParticles
TemporalDescription
TimeSpan
StartDate
2011-01-01 00:00:00
StopDate
2013-06-30 23:59:00
Note
Time format in data files is year-month-day hour:minute:seconds. Data file may fill out the first month and last month with flags.
Cadence
PT2S
Caveats
Flags=-99999.0
Keywords
2 s
geosynchronous
GOES
Magnetospheric Electron Detector
Parameter #1
Name
Seconds of the Month
ParameterKey
Time
Description
Time format in data files is year-month-day hour:minute:seconds.
Support
Parameter #2
Name
Quality flag for electrons with energy from 50 to 100 keV
ParameterKey
M_1ME2_QUAL_FLAG
Description
Quality flag non-zero value indicates data quality issue.
ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
Parameter #3
Name
Uncorrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_1ME2_UDTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 1 not corrected for dead time errors or other sources of contamination.
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #4
Name
Corrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_1ME2_DTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 1 corrected for dead time errors but not other sources of contamination
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #5
Name
Average flux of electrons with energy from 50 to 100 keV
ParameterKey
M_1ME2_DTC_UNCOR_FLUX
Description
Average flux of 75 keV electrons measured by telescope 1 corrected for dead time errors but not other sources of contamination.
Units
(cm^2 s sr)^-1
ValidMin
1.0
ValidMax
1.0e7
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
NumberFlux
EnergyRange
Parameter #6
Name
Quality flag for electrons with energy from 50 to 100 keV
ParameterKey
M_2ME2_QUAL_FLAG
Description
Quality flag non-zero value indicates data quality issue.
ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
Parameter #7
Name
Uncorrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_2ME2_UDTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 2 not corrected for dead time errors or other sources of contamination.
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #8
Name
Corrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_2ME2_DTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 2 corrected for dead time errors but not other sources of contamination
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #9
Name
Average flux of electrons with energy from 50 to 100 keV
ParameterKey
M_2ME2_DTC_UNCOR_FLUX
Description
Average flux of 75 keV electrons measured by telescope 2 corrected for dead time errors but not other sources of contamination.
Units
(cm^2 s sr)^-1
ValidMin
1.0
ValidMax
1.0e7
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
NumberFlux
EnergyRange
Parameter #10
Name
Quality flag for electrons with energy from 50 to 100 keV
ParameterKey
M_3ME2_QUAL_FLAG
Description
Quality flag non-zero value indicates data quality issue.
ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
Parameter #11
Name
Uncorrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_3ME2_UDTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 3 not corrected for dead time errors or other sources of contamination.
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #12
Name
Corrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_3ME2_DTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 3 corrected for dead time errors but not other sources of contamination
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #13
Name
Average flux of electrons with energy from 50 to 100 keV
ParameterKey
M_3ME2_DTC_UNCOR_FLUX
Description
Average flux of 75 keV electrons measured by telescope 3 corrected for dead time errors but not other sources of contamination.
Units
(cm^2 s sr)^-1
ValidMin
1.0
ValidMax
1.0e7
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
NumberFlux
EnergyRange
Parameter #14
Name
Quality flag for electrons with energy from 50 to 100 keV
ParameterKey
M_4ME2_QUAL_FLAG
Description
Quality flag non-zero value indicates data quality issue.
ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
Parameter #15
Name
Uncorrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_4ME2_UDTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 4 not corrected for dead time errors or other sources of contamination.
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #16
Name
Corrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_4ME2_DTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 4 corrected for dead time errors but not other sources of contamination
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #17
Name
Average flux of electrons with energy from 50 to 100 keV
ParameterKey
M_4ME2_DTC_UNCOR_FLUX
Description
Average flux of 75 keV electrons measured by telescope 4 corrected for dead time errors but not other sources of contamination.
Units
(cm^2 s sr)^-1
ValidMin
1.0
ValidMax
1.0e7
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
NumberFlux
EnergyRange
Parameter #18
Name
Quality flag for electrons with energy from 50 to 100 keV
ParameterKey
M_5ME2_QUAL_FLAG
Description
Quality flag non-zero value indicates data quality issue.
ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
Parameter #19
Name
Uncorrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_5ME2_UDTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 5 not corrected for dead time errors or other sources of contamination.
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #20
Name
Corrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_5ME2_DTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 5 corrected for dead time errors but not other sources of contamination
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #21
Name
Average flux of electrons with energy from 50 to 100 keV
ParameterKey
M_5ME2_DTC_UNCOR_FLUX
Description
Average flux of 75 keV electrons measured by telescope 5 corrected for dead time errors but not other sources of contamination.
Units
(cm^2 s sr)^-1
ValidMin
1.0
ValidMax
1.0e7
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
NumberFlux
EnergyRange
Parameter #22
Name
Quality flag for electrons with energy from 50 to 100 keV
ParameterKey
M_6ME2_QUAL_FLAG
Description
Quality flag non-zero value indicates data quality issue.
ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
Parameter #23
Name
Uncorrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_6ME2_UDTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 6 not corrected for dead time errors or other sources of contamination.
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #24
Name
Corrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_6ME2_DTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 6 corrected for dead time errors but not other sources of contamination
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #25
Name
Average flux of electrons with energy from 50 to 100 keV
ParameterKey
M_6ME2_DTC_UNCOR_FLUX
Description
Average flux of 75 keV electrons measured by telescope 6 corrected for dead time errors but not other sources of contamination.
Units
(cm^2 s sr)^-1
ValidMin
1.0
ValidMax
1.0e7
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
NumberFlux
EnergyRange
Parameter #26
Name
Quality flag for electrons with energy from 50 to 100 keV
ParameterKey
M_7ME2_QUAL_FLAG
Description
Quality flag non-zero value indicates data quality issue.
ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
Parameter #27
Name
Uncorrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_7ME2_UDTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 7 not corrected for dead time errors or other sources of contamination.
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #28
Name
Corrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_7ME2_DTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 7 corrected for dead time errors but not other sources of contamination
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #29
Name
Average flux of electrons with energy from 50 to 100 keV
ParameterKey
M_7ME2_DTC_UNCOR_FLUX
Description
Average flux of 75 keV electrons measured by telescope 7 corrected for dead time errors but not other sources of contamination.
Units
(cm^2 s sr)^-1
ValidMin
1.0
ValidMax
1.0e7
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
NumberFlux
EnergyRange
Parameter #30
Name
Quality flag for electrons with energy from 50 to 100 keV
ParameterKey
M_8ME2_QUAL_FLAG
Description
Quality flag non-zero value indicates data quality issue.
ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
Parameter #31
Name
Uncorrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_8ME2_UDTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 8 not corrected for dead time errors or other sources of contamination.
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #32
Name
Corrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_8ME2_DTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 8 corrected for dead time errors but not other sources of contamination
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #33
Name
Average flux of electrons with energy from 50 to 100 keV
ParameterKey
M_8ME2_DTC_UNCOR_FLUX
Description
Average flux of 75 keV electrons measured by telescope 8 corrected for dead time errors but not other sources of contamination.
Units
(cm^2 s sr)^-1
ValidMin
1.0
ValidMax
1.0e7
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
NumberFlux
EnergyRange
Parameter #34
Name
Quality flag for electrons with energy from 50 to 100 keV
ParameterKey
M_9ME2_QUAL_FLAG
Description
Quality flag non-zero value indicates data quality issue.
ValidMin
0
ValidMax
4294967295
FillValue
99999
Support
Parameter #35
Name
Uncorrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_9ME2_UDTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 9 not corrected for dead time errors or other sources of contamination.
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #36
Name
Corrected Count rate of electrons with energy from 50 to 100 keV
ParameterKey
M_9ME2_DTC_UNCOR_CR
Description
Average count rate of electrons with energy from 50 to 100 keV measured by telescope 9 corrected for dead time errors but not other sources of contamination
Units
s^-1
ValidMin
0.0
ValidMax
1.0e6
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
CountRate
EnergyRange
Parameter #37
Name
Average flux of electrons with energy from 50 to 100 keV
ParameterKey
M_9ME2_DTC_UNCOR_FLUX
Description
Average flux of 75 keV electrons measured by telescope 9 corrected for dead time errors but not other sources of contamination.
Units
(cm^2 s sr)^-1
ValidMin
1.0
ValidMax
1.0e7
FillValue
-99999
Particle
ParticleType
Electron
ParticleQuantity
NumberFlux
EnergyRange