HPDE.io

GOES 7 Energetic Particle Monitor at 3 s Time Resolution

ResourceID
spase://NOAA/NumericalData/GOES/7/EPM/PT3S

Description

The GOES 7 EPM data set contains various parameters at 3 s time resolution. Within the data files is the time given as seconds of the month where the date is given in the filename, a flag word that provides information on the data and satellite command state in a flagword, and the measured counts for a subset of available channels, which are indicated by the flagword.

View XML | View JSON | Edit

Details

Version:2.3.0

NumericalData

ResourceID
spase://NOAA/NumericalData/GOES/7/EPM/PT3S
ResourceHeader
ResourceName
GOES 7 Energetic Particle Monitor at 3 s Time Resolution
AlternateName
GOES 7 EPM data
ReleaseDate
2019-05-05 12:34:56Z
Description

The GOES 7 EPM data set contains various parameters at 3 s time resolution. Within the data files is the time given as seconds of the month where the date is given in the filename, a flag word that provides information on the data and satellite command state in a flagword, and the measured counts for a subset of available channels, which are indicated by the flagword.

Acknowledgement
NOAA Environmental Research Laboratories, Herbert H. Sauer, Terry G. Onsager
Contacts
RolePersonStartDateStopDateNote
1.PrincipalInvestigatorspase://SMWG/Person/Herbert.H.Sauer
2.PrincipalInvestigatorspase://SMWG/Person/Terry.Onsager
3.MetadataContactspase://SMWG/Person/James.M.Weygand
InformationURL
Name
GOES 7 Energetic Particle Monitor
URL
Description

Introduction to the GOES 7 Energetic Particle Monitor.

InformationURL
Name
GOES 7 Energetic Particle Monitor Data File Information
URL
Description

Additional GOES EPM information.

InformationURL
Name
GOES 7 Energetic Particle Monitor Additional Data File Information
URL
Description

Additional GOES EPM data file information.

PriorIDs
spase://VMO/NumericalData/GOES/7/EPM/HighRes/PT3S
spase://VMO/NumericalData/GOES7/EPM/HighRes/PT3S
spase://VMO/NumericalData/GOES/7/EPM/PT3S
spase://VSPO/NumericalData/GOES/7/EPM/PT3S
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
Direct access to the GOES 7 EPM data
URL
Description

Direct link to the GOES 7 EPM data in FITS format as well as the energetic particle data from other GOES spacecraft. The data are sorted by year. The file names indicates the data type, spacecraft number, year, month, and resolution. For example, P0137607.FIT indicates particle data (P) for spacecraft 1 (01) at 3 s time resolution (3) from July 1976 (7607). Note that spacecraft IDs 91 and 92 refer to SMS satellites, not GOES.

Format
FITS
Encoding
None
Acknowledgement
NOAA Environmental Research Laboratories, Herbert H. Sauer, Terry G. Onsager
ProcessingLevel
Calibrated
ProviderResourceName
NOAA GOES 7 EPM
ProviderProcessingLevel
Level-2
InstrumentIDs
MeasurementType
EnergeticParticles
TemporalDescription
TimeSpan
StartDate
1987-03-01 00:00:00
StopDate
1992-12-31 00:00:00
Note
Time format in data files is seconds of the month. The year and month are derived from the file name.
Cadence
PT3S
Caveats
The flag values are equal to 32711000, these data are temporarily offline until further notice
Keywords
3 s
geosynchronous
GOES
energetic particle monitor
energetic particles
Parameter #1
Name
Seconds of the Month
ParameterKey
Time
Description

Time is given as seconds of the month. The year and month values are derived from the filename.

Cadence
PT3S
Support
SupportQuantity
Temporal
Parameter #2
Name
Flag Word
ParameterKey
Flag Word
Description

The flag word contains packed information about the data such as the multiplex counter, data processing error flag, the satellite command state, and archive version number. The multiplex counter value indicates the three data channels from which the counts/s are recorded. Because the multiplex counter can change every three seconds is not possible to give the data channel, energy range, and other information in the next three parameters. The multiplex counter is equal to flagword mod 16. With the multiplex counter use the look up table at see https://satdat.ngdc.noaa.gov/sem/goes/software/part.txt to determine the energy channels, the associated particle, and the energy range.

Cadence
PT3S
Support
SupportQuantity
Other
Parameter #3
Name
GOES 7 EPM 2-Channel Multiplexer at 3 s Time Resolution
ParameterKey
MPX2
Description

EPM 2-Channel Multiplexer for GOES 7 in units of counts/s. These data are the measured counts/s from the 2nd channel as identified by yhe multiplex counter given in the flag word.

Caveats
The user must know what the multiplex count value is from the flagword
Cadence
PT3S
Units
s^-1
Particle
ParticleType
Proton
ParticleType
Electron
Qualifier
Scalar
ParticleQuantity
Counts
Parameter #4
Name
GOES 7 EPM 4-Channel Multiplexer at 3 s Time Resolution
ParameterKey
MPX4
Description

EPM 4-Channel Multiplexer for GOES 7 in units of counts/s. These data are the measured counts/s from the 2nd channel as identified by yhe multiplex counter given in the flag word.

Caveats
The user must know what the multiplex count value is from the flagword
Cadence
PT3S
Units
s^-1
Particle
ParticleType
Proton
ParticleType
Electron
Qualifier
Scalar
ParticleQuantity
Counts
Parameter #5
Name
GOES 7 EPM 8-Channel Multiplexer at 3 s Time Resolution
ParameterKey
MPX8
Description

EPM 8-Channel Multiplexer for GOES 7 in units of counts/s. These data are the measured counts/s from the 2nd channel as identified by yhe multiplex counter given in the flag word.

Caveats
The user must know what the multiplex count value is from the flagword
Cadence
PT3S
Units
s^-1
Particle
ParticleType
Proton
ParticleType
Electron
Qualifier
Scalar
ParticleQuantity
Counts