HPDE.io

Cluster Ion Spectrometry (CIS)

ResourceID
spase://SMWG/Instrument/Cluster-Tango/CIS

Description

This instrument (CIS: Cluster Ion Spectrometry) is capable of obtaining full 3D ion distributions with high time resolution (in one spacecraft spin) and mass-per-charge resolution. The experiment consists of two different instruments, a Hot Ion Analyzer (HIA) and a time-of-flight Ion Composition and Distribution Function analyzer (CODIF). Extensive on-board processing is done, within its dual-processor Data Processing System (DPS). CODIF determines the distributions of the major ion species with energies from spacecraft potential to 40 KeV/charge with an angular resolution of 22.5 x 10.25 degrees and with two different sensitivities. The CODIF instrument uses electrostatic deflection to select by energy per charge, with subsequent time-of-flight analysis. The sensor primarily covers the energy range 0.02--40 KeV/charge, but with additional pre-acceleration for energies below 25 eV/charge, the range is extended to energies as low as the spacecraft potential. The HIA does not measure mass, but extends the dynamic range to the highest ion fluxes, and has angular resolution capability of 5.6 x 5.6 degrees for ion-beam and solar-wind measurements. The HIA is a symmetric quadrispherical analyzer of top-hat geometry, and uses microchannel-plate electron multipliers and position encoding by discrete anodes. A 2D distribution is obtained once per 62.5 ms, and a full 3D distribution of ions in the energy range ~5 eV/charge to 32 KeV/charge is obtained every 4 s. For more details of the Cluster mission, the spacecraft, and its instruments, see the report Cluster: mission, payload and supporting activities,'' March 1993, ESA SP-1159, and the included articleThe Cluster Ion Spectrometry Experiment,'' by H. Reme et al., from which this information was obtained.

View XML | View JSON | Edit

Details

Version:2.0.0

Instrument

ResourceID
spase://SMWG/Instrument/Cluster-Tango/CIS
ResourceHeader
ResourceName
Cluster Ion Spectrometry (CIS)
AlternateName
CIS
ReleaseDate
2019-05-05 12:34:56Z
Description

This instrument (CIS: Cluster Ion Spectrometry) is capable of obtaining full 3D ion distributions with high time resolution (in one spacecraft spin) and mass-per-charge resolution. The experiment consists of two different instruments, a Hot Ion Analyzer (HIA) and a time-of-flight Ion Composition and Distribution Function analyzer (CODIF). Extensive on-board processing is done, within its dual-processor Data Processing System (DPS). CODIF determines the distributions of the major ion species with energies from spacecraft potential to 40 KeV/charge with an angular resolution of 22.5 x 10.25 degrees and with two different sensitivities. The CODIF instrument uses electrostatic deflection to select by energy per charge, with subsequent time-of-flight analysis. The sensor primarily covers the energy range 0.02--40 KeV/charge, but with additional pre-acceleration for energies below 25 eV/charge, the range is extended to energies as low as the spacecraft potential. The HIA does not measure mass, but extends the dynamic range to the highest ion fluxes, and has angular resolution capability of 5.6 x 5.6 degrees for ion-beam and solar-wind measurements. The HIA is a symmetric quadrispherical analyzer of top-hat geometry, and uses microchannel-plate electron multipliers and position encoding by discrete anodes. A 2D distribution is obtained once per 62.5 ms, and a full 3D distribution of ions in the energy range ~5 eV/charge to 32 KeV/charge is obtained every 4 s. For more details of the Cluster mission, the spacecraft, and its instruments, see the report Cluster: mission, payload and supporting activities,'' March 1993, ESA SP-1159, and the included articleThe Cluster Ion Spectrometry Experiment,'' by H. Reme et al., from which this information was obtained.

Contacts
RolePersonStartDateStopDateNote
1.PrincipalInvestigatorspase://SMWG/Person/Henri.Reme
InformationURL
Name
NSSDC's Master Catalog
URL
Description

Information about the Cluster Ion Spectrometry (CIS) experiment on the Cluster 2/FM5 (Tango) mission.

InformationURL
Name
Space Science Reviews Journal Article
URL
Description

Detailed information about the Cluster Ion Spectrometry (CIS) experiment.

PriorIDs
spase://SMWG/Instrument/Cluster2-Tango/CIS
InstrumentType
EnergeticParticleInstrument
InvestigationName
Cluster Ion Spectrometry (CIS) on Cluster 2/FM8 (Tango)
ObservatoryID