HPDE.io

Space Environment Monitor (SEM)

ResourceID
spase://SMWG/Instrument/GOES/7/SEM

Description

The Space Environment Monitor Subsystem (SEM) measures in situ the effect of the sun on the near-earth solar-terrestrial electromagnetic environment on a real-time basis. This information is provided to the Space Environment Services Center where it is used for "near-space weather" reports. These reports, which include solar activity, are important to the operators of communication, navigation, electric power transmission systems, and satellites.
The SEM consists of four instruments. The Energetic Particle Sensor (EP8,formerly called EPS) makes flux measurements of protons in the 0.8 to 500 MeV range. The High Energy Proton and Alpha Detector (HEPAD) monitors protons in four energy ranges above 350 MeV and alpha particles in two energy ranges above 640 MeV/nucleon. The solar X-Ray Sensor permits real-time determination of the solar x-ray emission in two spectral bands: 0.5-5 angstroms and 1-8 angstroms. The Magnetic Field Sensor (MFS) allows for the real-time determination of the magnitude and orientation of the magnetic field. Data will be telemetered twice a second for magnetic fields having a magnitude of +/- 1000 nanotesla (nT).

View XML | View JSON | Edit

Details

Version:2.2.0

Instrument

ResourceID
spase://SMWG/Instrument/GOES/7/SEM
ResourceHeader
ResourceName
Space Environment Monitor (SEM)
ReleaseDate
2019-05-05 12:34:56Z
Description

The Space Environment Monitor Subsystem (SEM) measures in situ the effect of the sun on the near-earth solar-terrestrial electromagnetic environment on a real-time basis. This information is provided to the Space Environment Services Center where it is used for "near-space weather" reports. These reports, which include solar activity, are important to the operators of communication, navigation, electric power transmission systems, and satellites.
The SEM consists of four instruments. The Energetic Particle Sensor (EP8,formerly called EPS) makes flux measurements of protons in the 0.8 to 500 MeV range. The High Energy Proton and Alpha Detector (HEPAD) monitors protons in four energy ranges above 350 MeV and alpha particles in two energy ranges above 640 MeV/nucleon. The solar X-Ray Sensor permits real-time determination of the solar x-ray emission in two spectral bands: 0.5-5 angstroms and 1-8 angstroms. The Magnetic Field Sensor (MFS) allows for the real-time determination of the magnitude and orientation of the magnetic field. Data will be telemetered twice a second for magnetic fields having a magnitude of +/- 1000 nanotesla (nT).

Acknowledgement
NOAA Environmental Research Laboratories; Dr. Ronald Zwickl; Dr. Harold Leinbach; Dr. Herbert H. Sauer; Dr. Terry Onsager; Dr. Howard Singer; Mr. Howard Garcia
Contacts
RolePersonStartDateStopDateNote
1.GeneralContactspase://SMWG/Person/Ronald.D.Zwickl
2.PrincipalInvestigatorspase://SMWG/Person/Herbert.H.Sauer
3.PrincipalInvestigatorspase://SMWG/Person/Howard.J.Singer
4.PrincipalInvestigatorspase://SMWG/Person/Harold.Leinbach
5.PrincipalInvestigatorspase://SMWG/Person/Terry.Onsager
6.PrincipalInvestigatorspase://SMWG/Person/Howard.A.Garcia
InformationURL
Name
GOES 7 Energetic Particle Monitor
URL
Description

Introduction to the GOES 7 Energetic Particle Sensor.

InformationURL
Name
GOES 7 Energetic Particle Sensor Data File Information
URL
Description

Additional GOES EPM information.

InformationURL
Name
GOES 7 Energetic Particle Sensor Additional Data File Information
URL
Description

Additional GOES EPM data file information.

InformationURL
Name
GOES 7 Magnetic Field Monitor
URL
Description

Introduction to the GOES 7 Magnetic Field Monitor.

InformationURL
Name
GOES 7 Space Environment Monitor
URL
Description

Additional GOES Magnetic Field Monitor information.

InformationURL
Name
GOES 7 Magnetic Field Monitor Example ASCII file
URL
Description

Additional GOES Magnetic Field Monitor header information.

InformationURL
Name
GOES 7 Solar X-Ray Monitor
URL
Description

Additional GOES Solar X-Ray Monitor information.

InstrumentType
Magnetometer
InstrumentType
EnergeticParticleInstrument
InstrumentType
IonChamber
InvestigationName
Space Environment Monitor (SEM) on GOES 7
ObservatoryID
Caveats
From http://goes.ngdc.noaa.gov/data/avg/readme.txt: Electron Data Quality The Electron detector responds significantly to protons above 32 MeV; therefore, electron data are contaminated when a proton event is in progress. Beginning with GOES-8 the electron data have had a preliminary correction applied, however, even these data are not to be considered research quality at this time. In 1991 the telescope component of the GOES-7 energetic particle detector system experienced episodes of malfunction (noise). The first period began at 0330 UT, October 18, 1991 and extended to November 5, 1991. The detector was commanded off for 12 hours. At turn-on the detector appeared to have recovered, but failed again on November 11, with a rerecovery on November 12 after a second turn-off of three hours. The detector has since operated normally. The noise periods may be identified by unusually high rates being shown by the P1 channel and the derived > 1 MeV integral channel. Currently, the GOES-7 Energetic Particle Sensor is left turned off for 4 hours after eclipse to minimize bad data.