Quadrispherical Plasma Analyzer

ResourceID
spase://SMWG/Instrument/Pioneer11/PLS

Description

The instrument consisted of dual 90-deg quadrispherical electrostatic analyzers, one with 26 individual particle detectors and the other with 5 current collectors. The system was capable of measuring incident plasma distribution parameters over the energy range 0.1 to 18 keV for protons and approximately 1 to 500 eV for electrons. The high-resolution analyzer with a constant of 9 keV/Q per kV applied to the plates, had a mean plate radius of 9 cm and separation of 0.5 cm. This analyzer was used to measure ions only, and had 26 channeltrons mounted on the semicircular exit to the analyzer. The aperture pointed through a wide slit in the back of the spacecraft high-gain antenna reflector and pointed along the spin axis toward the earth (and therefore the sun). The edges of the antenna reflector limited the viewing of the instrument to 73 deg with respect to the spin axis. The channeltrons covered a range of plus or minus 51 deg. Each channeltron near the center covered 3 deg and approximately 8 deg near the edges of the analyzer. The angular width perpendicular to the long angular width was about 2 deg. In half the spin period the whole cone of half-angle 51 deg centered on the sun was swept out. A medium-energy analyzer with a mean radius of 12 cm and a 1-cm plate separation (constant of 6 keV/Q per kV applied) was used to detect both ions and electrons. The detectors were five flat-surface current collectors. The three center collectors each covered 15 deg and covered the angular range of plus or minus 22.5 deg from the spin axis. The two outside collectors had an angular width of 47.5 deg and were located at plus or minus 46.25 deg from the center of the analyzer. There was a variety of possible operating modes for the experiment; however, the principal mode utilized during the encounter phase was one in which the analyzer plate potential was stepped through its range every one-half revolution of the spacecraft, and all current collectors or channeltrons were read out at the peak flux roll angle. The high and medium resolution analyzers operated independently, so a cross check between these analyzers was possible. The dynamic range for the particle fluxes was from 1.0E+2 to 3.0E+9/(sq cm-s) and the proton temperature down to 2.0E+3 deg K could be ascertained. Data include the interplanetary region. Detector A was turned off on September 16, 1987.

View XML | View JSON | Edit

Details

Version:2.0.0

Instrument

ResourceID
spase://SMWG/Instrument/Pioneer11/PLS
ResourceHeader
ResourceName
Quadrispherical Plasma Analyzer
ReleaseDate
2019-05-05 12:34:56Z
Description

The instrument consisted of dual 90-deg quadrispherical electrostatic analyzers, one with 26 individual particle detectors and the other with 5 current collectors. The system was capable of measuring incident plasma distribution parameters over the energy range 0.1 to 18 keV for protons and approximately 1 to 500 eV for electrons. The high-resolution analyzer with a constant of 9 keV/Q per kV applied to the plates, had a mean plate radius of 9 cm and separation of 0.5 cm. This analyzer was used to measure ions only, and had 26 channeltrons mounted on the semicircular exit to the analyzer. The aperture pointed through a wide slit in the back of the spacecraft high-gain antenna reflector and pointed along the spin axis toward the earth (and therefore the sun). The edges of the antenna reflector limited the viewing of the instrument to 73 deg with respect to the spin axis. The channeltrons covered a range of plus or minus 51 deg. Each channeltron near the center covered 3 deg and approximately 8 deg near the edges of the analyzer. The angular width perpendicular to the long angular width was about 2 deg. In half the spin period the whole cone of half-angle 51 deg centered on the sun was swept out. A medium-energy analyzer with a mean radius of 12 cm and a 1-cm plate separation (constant of 6 keV/Q per kV applied) was used to detect both ions and electrons. The detectors were five flat-surface current collectors. The three center collectors each covered 15 deg and covered the angular range of plus or minus 22.5 deg from the spin axis. The two outside collectors had an angular width of 47.5 deg and were located at plus or minus 46.25 deg from the center of the analyzer. There was a variety of possible operating modes for the experiment; however, the principal mode utilized during the encounter phase was one in which the analyzer plate potential was stepped through its range every one-half revolution of the spacecraft, and all current collectors or channeltrons were read out at the peak flux roll angle. The high and medium resolution analyzers operated independently, so a cross check between these analyzers was possible. The dynamic range for the particle fluxes was from 1.0E+2 to 3.0E+9/(sq cm-s) and the proton temperature down to 2.0E+3 deg K could be ascertained. Data include the interplanetary region. Detector A was turned off on September 16, 1987.

Contacts
RolePersonStartDateStopDateNote
1.PrincipalInvestigatorspase://SMWG/Person/Aaron.Barnes
InformationURL
Name
NSSDC's Master Catalog
URL
Description

Information about the Quadrispherical Plasma Analyzer experiment on the Pioneer 11 mission.

InstrumentType
QuadrisphericalAnalyser
InvestigationName
Quadrispherical Plasma Analyzer on Pioneer 11
ObservatoryID